Reference standard

Critically operated nozzles are used to generate the highly stable volume flow in the reference standard.

Critically operated nozzles are used to generate the highly stable volume flow in the reference standard. Their operating principle is based on the fact that sound velocity is set up in the neck section of an appropriately shaped nozzle on reaching a defined critical pressure ratio.

Product Websites

Global Websites

Elster Kromschroeder Docuthek

You can find all Kromschroeder documents here.

 www.docuthek.com

Elster Kromschroeder courses

Our specialist courses are intended for operators of process heat systems, service personnel as well as planners and field workers.

more

 

BK G4 3D Animation

Start the animation

 

 

 

 

 

Virtual walkaround ISH 2009

Elster GmbH

P.O. BOX 2809

D-49018 Osnabrück

Strotheweg 1

D-49504 Lotte (Büren)

Germany

 +49 541 1214-0

 +49 541 1214-370

info(at)kromschroeder.com

 

Reference standard

Reference standard

Critically operated nozzles are used to generate the highly stable volume flow in the reference standard. Their operating principle is based on the fact that sound velocity is set up in the neck section of an appropriately shaped nozzle on reaching a defined critical pressure ratio. The volume flow is then principally dependent only on the cross-section through which it flows. The volumetric measurement can thus essentially be traced back to a measurement of time. This can significantly reduce the test duration.

 

Qmax-nozzle

In the overall design of the nozzle reference standard, our design engineers were able to provide nozzles that can be independently replaced by the user through the use of innovative clamping technology and freely-configurable removable baseplates (for three nozzles).

Qmin-nozzle

This solution provides the following benefits for the user:

•    Individual and flexible adaptation to the test task

•    Simple, visual status checks on the nozzles by operating

      personnel

•    Safe, selective and economical replacement of worn nozzles

•    Low-cost, non-stationary testing of the reference standards

      used

•    No cost-intensive downtime required for calibrating the whole

      system

Removable nozzle baseplate

In addition, the standard product series can be supplemented later on with additional volume flows (QRLab) or by a second reference standard operated in parallel (QRManufacturer), without taking up any more space.

Connecting additional testing lines (temperature test cabinet, domestic and industrial meters) allows the implementation of all standard requirements.

 

 

Testing line
Reference standard
Signal recording