{"id":11970,"date":"2018-07-25T01:24:46","date_gmt":"2018-07-24T23:24:46","guid":{"rendered":"https:\/\/www.kromschroeder.de\/21-gas-measuring-train\/"},"modified":"2018-07-25T01:24:47","modified_gmt":"2018-07-24T23:24:47","slug":"21-gas-measuring-train","status":"publish","type":"page","link":"https:\/\/www.kromschroeder.de\/en\/kromschroeder-system-technology\/gas-systems\/gas-utilization\/gas-inlet-sections\/21-gas-measuring-train\/","title":{"rendered":"21 Gas measuring train"},"content":{"rendered":"<p>[et_pb_section bb_built=&#8221;1&#8243; fullwidth=&#8221;on&#8221; specialty=&#8221;off&#8221; _builder_version=&#8221;3.0.89&#8243; next_background_color=&#8221;#000000&#8243; global_module=&#8221;3071&#8243;][et_pb_fullwidth_menu global_parent=&#8221;3071&#8243; _builder_version=&#8221;3.0.89&#8243; menu_id=&#8221;52&#8243; submenu_direction=&#8221;downwards&#8221; fullwidth_menu=&#8221;off&#8221; background_layout=&#8221;dark&#8221; background_color=&#8221;#000000&#8243; active_link_color=&#8221;#aaaaaa&#8221; dropdown_menu_text_color=&#8221;#ffffff&#8221; mobile_menu_text_color=&#8221;#000000&#8243; dropdown_menu_line_color=&#8221;#ffffff&#8221; mobile_menu_bg_color=&#8221;#ffffff&#8221; \/][\/et_pb_section][et_pb_section bb_built=&#8221;1&#8243; fullwidth=&#8221;on&#8221; specialty=&#8221;off&#8221; prev_background_color=&#8221;#000000&#8243; next_background_color=&#8221;#000000&#8243; _builder_version=&#8221;3.8.1&#8243; global_module=&#8221;10523&#8243;][et_pb_fullwidth_menu admin_label=&#8221;KST Men\u00fc&#8221; global_parent=&#8221;10523&#8243; _builder_version=&#8221;3.8.1&#8243; menu_id=&#8221;83&#8243; submenu_direction=&#8221;downwards&#8221; fullwidth_menu=&#8221;off&#8221; background_color=&#8221;#3f3f3f&#8221; background_layout=&#8221;dark&#8221; \/][\/et_pb_section][et_pb_section bb_built=&#8221;1&#8243; _builder_version=&#8221;3.0.60&#8243; custom_padding=&#8221;0px||0px|&#8221; next_background_color=&#8221;#f1f1f1&#8243; prev_background_color=&#8221;#000000&#8243; global_module=&#8221;1488&#8243;][et_pb_row global_parent=&#8221;1488&#8243; custom_padding=&#8221;0px||0px|&#8221; background_position_1=&#8221;top_left&#8221; background_repeat_1=&#8221;no-repeat&#8221; _builder_version=&#8221;3.0.60&#8243; background_size=&#8221;initial&#8221; background_position=&#8221;top_left&#8221; background_repeat=&#8221;repeat&#8221;][et_pb_column type=&#8221;4_4&#8243;][et_pb_dmb_breadcrumbs global_parent=&#8221;1488&#8243; font_icon=&#8221;%%36%%&#8221; _builder_version=&#8221;3.0.89&#8243; body_font_size=&#8221;11px&#8221; body_text_color=&#8221;#666666&#8243; link_text_color=&#8221;#666666&#8243;]<\/p>\n<div class=\"et_pb_module et_pb_dmb_breadcrumbs_1 et_pb_dmb_breadcrumbs\" style=\"visibility: hidden;\">\n<ol>\n<li><a href=\"https:\/\/www.kromschroeder.de\">Startseite<\/a><\/li>\n<\/ol>\n<\/div>\n<p>[\/et_pb_dmb_breadcrumbs][\/et_pb_column][\/et_pb_row][\/et_pb_section][et_pb_section bb_built=&#8221;1&#8243; background_color=&#8221;#f1f1f1&#8243; disabled_on=&#8221;off|off|&#8221; _builder_version=&#8221;3.0.89&#8243; custom_padding=&#8221;17px|0px|7px|0px&#8221; prev_background_color=&#8221;#ffffff&#8221; next_background_color=&#8221;#ffffff&#8221;][et_pb_row custom_padding=&#8221;0px||0px|&#8221; custom_margin=&#8221;0px||0px|&#8221; background_position_1=&#8221;top_left&#8221; background_repeat_1=&#8221;no-repeat&#8221; _builder_version=&#8221;3.0.89&#8243;][et_pb_column type=&#8221;4_4&#8243;][et_pb_text _builder_version=&#8221;3.8.1&#8243; module_alignment=&#8221;left&#8221; border_style=&#8221;solid&#8221;]<\/p>\n<h1 class=\"csc-firstHeader\">KST &#8211; KROMSCHR\u00d6DER SYSTEM TECHNOLOGY<\/h1>\n<p>[\/et_pb_text][\/et_pb_column][\/et_pb_row][\/et_pb_section][et_pb_section bb_built=&#8221;1&#8243; _builder_version=&#8221;3.0.47&#8243; custom_padding=&#8221;21px|0px|54px|0px&#8221; prev_background_color=&#8221;#f1f1f1&#8243;][et_pb_row background_color=&#8221;#f1f1f1&#8243; background_color_1=&#8221;#f1f1f1&#8243; background_position_1=&#8221;top_left&#8221; background_position_2=&#8221;top_left&#8221; background_repeat_1=&#8221;no-repeat&#8221; background_repeat_2=&#8221;no-repeat&#8221; _builder_version=&#8221;3.0.89&#8243; use_custom_gutter=&#8221;on&#8221; gutter_width=&#8221;1&#8243;][et_pb_column type=&#8221;1_4&#8243;][et_pb_text admin_label=&#8221;docuthek monitor&#8221; _builder_version=&#8221;3.0.89&#8243; background_color=&#8221;#ffffff&#8221; custom_margin=&#8221;|10px||10px&#8221; custom_padding=&#8221;10px|10px|10px|10px&#8221; border_style=&#8221;solid&#8221; global_module=&#8221;1818&#8243; saved_tabs=&#8221;all&#8221; background_layout=&#8221;light&#8221; disabled_on=&#8221;on|on|&#8221; disabled=&#8221;off&#8221; border_style_all=&#8221;solid&#8221;]<\/p>\n<p><strong>DOCUTHEK<br \/>\n<\/strong><\/p>\n<p>You can find all documents here.<\/p>\n<form action=\" https:\/\/docuthek.kromschroeder.com\/documents\/index.php?lang=en&amp;menuid=31&amp;topmenu=31\" method=\"post\" target=\"blank\"><input name=\"searchvalue\" type=\"text\" value=\"\" placeholder=\"Search term\" \/><\/form>\n<p>&nbsp;<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-1820 alignnone\" src=\"https:\/\/b2fvdlvy.myraidbox.de\/wp-content\/uploads\/2017\/06\/dokulogo.gif\" alt=\"\" width=\"30\" height=\"30\" \/> <a href=\"https:\/\/docuthek.kromschroeder.com\/documents\/index.php?menuid=31&amp;topmenu=31?lang=en&amp;folder=1\" target=\"_blank\" rel=\"noopener\">docuthek.com<\/a><\/p>\n<p>[\/et_pb_text][\/et_pb_column][et_pb_column type=&#8221;1_2&#8243;][et_pb_text _builder_version=&#8221;3.10&#8243; module_alignment=&#8221;left&#8221; custom_padding=&#8221;0px|10px|10px|10px&#8221; border_style=&#8221;solid&#8221; header_line_height=&#8221;1.4em&#8221; header_line_height_last_edited=&#8221;on|desktop&#8221; header_font_size_last_edited=&#8221;on|phone&#8221; header_font_size_tablet=&#8221;25px&#8221; header_font_size_phone=&#8221;20px&#8221; background_color=&#8221;#ffffff&#8221;]<\/p>\n<h1>Gas inlet sections<\/h1>\n<p><a href=\"https:\/\/www.kromschroeder.de\/en\/kromschroeder-system-technology\/gas-systems\/gas-utilization\/gas-inlet-sections\/\" rel=\"noopener\">overview<\/a><\/p>\n<div class=\"content_typ_0\">\n<div id=\"tx_produktfinder_container\" class=\"produktfinderdetail\">\n<div class=\"zuruck\">\n<div class=\"rowrte\">\n<h1>Gas measuring train<\/h1>\n<div class=\"liste_beangeklickt\">With measurement, No pressure control, No tightness control, No SSV\/RV, Not calibratable, 1 stream, 0 valves<\/div>\n<div>Flowchart No.: 2.1<\/div>\n<div>Standard: <a href=\"https:\/\/www.kromschroeder.de\/en\/kromschroeder-system-technology\/gas-systems\/standards\/en-746-22010\/\">EN 746-2<\/a><\/div>\n<div class=\"bildmitbeschreibung\">\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-11491\" src=\"https:\/\/www.kromschroeder.de\/wp-content\/uploads\/2018\/07\/GM-21.png\" alt=\"\" width=\"515\" height=\"398\" srcset=\"https:\/\/www.kromschroeder.de\/wp-content\/uploads\/2018\/07\/GM-21.png 515w, https:\/\/www.kromschroeder.de\/wp-content\/uploads\/2018\/07\/GM-21-300x232.png 300w\" sizes=\"(max-width: 515px) 100vw, 515px\" \/><\/p>\n<table cellspacing=\"0\" cellpadding=\"0\">\n<tbody>\n<tr>\n<th class=\"center\">No.<\/th>\n<th>Component description<\/th>\n<th>Standards and Docuthek<\/th>\n<\/tr>\n<tr class=\"border0\">\n<td class=\"nummer\">010<\/td>\n<td>Manual isolating valve, e.g. manual valve AKT<\/td>\n<td>\n<div><a class=\"dinlink\" href=\"https:\/\/www.kromschroeder.de\/en\/kromschroeder-system-technology\/gas-systems\/standards\/en-746-22010\/5-2-gaseous-fuels\/5-2-2-required-safety-devices\/5-2-2-1-manual-isolating-valve\/\" rel=\"noopener\">5.2.2.1 Manual isolating valve<\/a><\/div>\n<div><a class=\"docutheklink\" href=\"http:\/\/docuthek.kromschroeder.com\/doclib\/main.php?language=1&amp;folderid=201010\/\" target=\"_blank\" rel=\"noopener\">Docuthek<\/a><\/div>\n<\/td>\n<\/tr>\n<tr class=\"border1\">\n<td class=\"nummer\">020<\/td>\n<td>Filter, e.g. gas filter GFK<\/p>\n<p class=\"newsbox\"><i><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-11301\" src=\"https:\/\/www.kromschroeder.de\/wp-content\/uploads\/2018\/07\/birne-f2w.jpg\" alt=\"\" width=\"40\" height=\"40\" \/><\/i><i>Our tip: at maximum flow rate, filters should show a pressure loss of no more than 10 mbar.<\/i><\/p>\n<\/td>\n<td>\n<div><a class=\"dinlink\" href=\"https:\/\/www.kromschroeder.de\/en\/kromschroeder-system-technology\/gas-systems\/standards\/en-746-22010\/5-2-gaseous-fuels\/5-2-2-required-safety-devices\/5-2-2-2-filter-strainer\/\" rel=\"noopener\">5.2.2.2 Filter\/strainer<\/a><\/div>\n<div><a class=\"docutheklink\" href=\"http:\/\/docuthek.kromschroeder.com\/doclib\/main.php?language=1&amp;folderid=201040\" target=\"_blank\" rel=\"noopener\">Docuthek<\/a><\/div>\n<\/td>\n<\/tr>\n<tr class=\"border0\">\n<td class=\"nummer\">030-040<\/td>\n<td>Pressure gauge, e.g. pressure gauge with capsule element KFM or pressure gauge with Bourdon tube RFM with pressure gauge valve DH or MH<\/td>\n<td>\n<div><a class=\"docutheklink\" href=\"http:\/\/docuthek.kromschroeder.com\/doclib\/main.php?language=1&amp;folderid=311040\" target=\"_blank\" rel=\"noopener\">Docuthek<\/a><\/div>\n<\/td>\n<\/tr>\n<tr class=\"border1\">\n<td class=\"nummer\">050<\/td>\n<td>Gas metering equipment, e.g. flow meters DM, DE<\/td>\n<td>\n<div><a class=\"docutheklink\" href=\"http:\/\/docuthek.kromschroeder.com\/doclib\/main.php?language=1&amp;folderid=211060\" target=\"_blank\" rel=\"noopener\">Docuthek<\/a><\/div>\n<\/td>\n<\/tr>\n<tr class=\"border0\">\n<td class=\"nummer\">060<\/td>\n<td>Low-pressure cut-off, e.g. pressure switch for gas DG<\/p>\n<p><i>The min. pressure switch setpoints to be adjusted depend on the installation location and the process conditions.<\/i><\/p>\n<p class=\"newsbox\"><i><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-11301\" src=\"https:\/\/www.kromschroeder.de\/wp-content\/uploads\/2018\/07\/birne-f2w.jpg\" alt=\"\" width=\"40\" height=\"40\" \/><\/i>Our tip: pressure switches should be installed preferably with horizontal or vertical diaphragm. Ensure that no dirt or moisture can penetrate the open ventilation ports.<\/p>\n<\/td>\n<td>\n<div><a class=\"dinlink\" href=\"https:\/\/www.kromschroeder.de\/en\/kromschroeder-system-technology\/gas-systems\/standards\/en-746-22010\/5-2-gaseous-fuels\/5-2-2-required-safety-devices\/5-2-2-5-air-and-gas-flow-and-pressure-detectors\/5-2-2-5-2-gas\/5-2-2-5-2-1-low-gas-protection\/\" rel=\"noopener\">5.2.2.5.2.1 Low gas protection<\/a><\/div>\n<div><a class=\"docutheklink\" href=\"http:\/\/docuthek.kromschroeder.com\/doclib\/main.php?language=1&amp;folderid=204020\" target=\"_blank\" rel=\"noopener\">Docuthek<\/a><\/div>\n<\/td>\n<\/tr>\n<tr class=\"border1\">\n<td class=\"nummer\">070<\/td>\n<td>High gas pressure protection, e.g. pressure switch for gas DG<\/p>\n<p><i>The max. pressure switch setpoints to be adjusted depend on the installation location and the process conditions.<\/i><\/p>\n<p class=\"newsbox\"><i><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-11301\" src=\"https:\/\/www.kromschroeder.de\/wp-content\/uploads\/2018\/07\/birne-f2w.jpg\" alt=\"\" width=\"40\" height=\"40\" \/><\/i>Our tip: pressure switches should be installed preferably with horizontal or vertical diaphragm. Ensure that no dirt or moisture can penetrate the open ventilation ports.<\/p>\n<\/td>\n<td>\n<div><a class=\"dinlink\" href=\"https:\/\/www.kromschroeder.de\/en\/kromschroeder-system-technology\/gas-systems\/standards\/en-746-22010\/5-2-gaseous-fuels\/5-2-2-required-safety-devices\/5-2-2-5-air-and-gas-flow-and-pressure-detectors\/5-2-2-5-2-gas\/5-2-2-5-2-2-high-gas-protection\/\" rel=\"noopener\">5.2.2.5.2.2 High gas protection<\/a><\/div>\n<div><a class=\"docutheklink\" href=\"http:\/\/docuthek.kromschroeder.com\/doclib\/main.php?language=1&amp;folderid=204020\" target=\"_blank\" rel=\"noopener\">Docuthek<\/a><\/div>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<div class=\"rowrte\">\n<h2>Application<\/h2>\n<p>Main gas train to EN 746-2. This is a part of the gas distribution system of the industrial thermoprocessing equipment (IThE), e.g. for downstream multiple burner systems.<\/p>\n<\/div>\n<div class=\"rowrte\">\n<h2>Function<\/h2>\n<p>If the main shut-off valve (010) is open, the gas flows through the filter (020). Any dirt in the gas or pipe system will be retained.<\/p>\n<p>The low-pressure cut-off (050) and the high gas pressure protection device (060) are part of the protective system. These compulsory safety devices are actuated separately by the process control system. In the case of insufficient or excessively high gas flow, the process control system will receive a signal and shut off the gas supply safely by closing two valves fitted in series. These valves can be part of the downstream burner system.<br \/>\nThe quantity of gas consumed can be read off the flow meter (050). The inlet and outlet pressure will be displayed on the pressure gauges (030\/040).<\/p>\n<\/div>\n<div class=\"rowrte\"><\/div>\n<\/div>\n<\/div>\n<div class=\"zuruck\"><a href=\"https:\/\/www.kromschroeder.de\/en\/kromschroeder-system-technology\/gas-systems\/gas-utilization\/gas-inlet-sections\/\" rel=\"noopener\">overview<\/a><\/div>\n<\/div>\n<\/div>\n<p>[\/et_pb_text][\/et_pb_column][et_pb_column type=&#8221;1_4&#8243;][et_pb_text admin_label=&#8221;docuthek tablet smart&#8221; _builder_version=&#8221;3.0.89&#8243; background_color=&#8221;#ffffff&#8221; custom_margin=&#8221;|10px||10px&#8221; custom_padding=&#8221;10px|10px|10px|10px&#8221; border_style=&#8221;solid&#8221; saved_tabs=&#8221;all&#8221; background_layout=&#8221;light&#8221; disabled_on=&#8221;off|off|on&#8221; disabled=&#8221;off&#8221; global_module=&#8221;2077&#8243; border_style_all=&#8221;solid&#8221;]<\/p>\n<p><strong>DOCUTHEK<br \/>\n<\/strong><\/p>\n<p>You can find all documents here.<\/p>\n<form action=\" https:\/\/docuthek.kromschroeder.com\/documents\/index.php?lang=en&amp;menuid=31&amp;topmenu=31\" method=\"post\" target=\"blank\"><input name=\"searchvalue\" type=\"text\" value=\"\" placeholder=\"Search term\" \/><\/form>\n<p>&nbsp;<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-1820 alignnone\" src=\"https:\/\/b2fvdlvy.myraidbox.de\/wp-content\/uploads\/2017\/06\/dokulogo.gif\" alt=\"\" width=\"30\" height=\"30\" \/> <a href=\"https:\/\/docuthek.kromschroeder.com\/documents\/index.php?menuid=31&amp;topmenu=31?lang=en&amp;folder=1\" target=\"_blank\" rel=\"noopener\">docuthek.com<\/a><\/p>\n<p>[\/et_pb_text][\/et_pb_column][\/et_pb_row][\/et_pb_section]<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Startseite KST &#8211; KROMSCHR\u00d6DER SYSTEM TECHNOLOGY DOCUTHEK You can find all documents here. &nbsp; docuthek.com Gas inlet sections overview Gas measuring train With measurement, No pressure control, No tightness control, No SSV\/RV, Not calibratable, 1 stream, 0 valves Flowchart No.: 2.1 Standard: EN 746-2 No. Component description Standards and Docuthek 010 Manual isolating valve, e.g. [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":11999,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_et_pb_use_builder":"on","_et_pb_old_content":"","_et_gb_content_width":"","footnotes":""},"class_list":["post-11970","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/www.kromschroeder.de\/en\/wp-json\/wp\/v2\/pages\/11970","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.kromschroeder.de\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.kromschroeder.de\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.kromschroeder.de\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.kromschroeder.de\/en\/wp-json\/wp\/v2\/comments?post=11970"}],"version-history":[{"count":0,"href":"https:\/\/www.kromschroeder.de\/en\/wp-json\/wp\/v2\/pages\/11970\/revisions"}],"up":[{"embeddable":true,"href":"https:\/\/www.kromschroeder.de\/en\/wp-json\/wp\/v2\/pages\/11999"}],"wp:attachment":[{"href":"https:\/\/www.kromschroeder.de\/en\/wp-json\/wp\/v2\/media?parent=11970"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}